Italy: fire safety

Fire safety checks for your kitchen, and how often they are due.

Checked

“Law” is a binding rule. “Official guidance” is not law, but inspectors expect it. “Chef Hygiene default” is a value the app checks against where no rule gives a number.

  • LawFire extinguisher checks and maintenance follow the technical standards and the maker’s instructions, and every check is recorded (decree DM 1 September 2021). The technician’s periodic check is every 6 months under standard UNI 9994-1; this is usual practice.
  • LawThe earthing system and any lightning protection are checked every 5 years, or every 2 years in places at higher fire risk. The ASL, ARPA or an authorised body does it (DPR 462/2001, art. 4).
  • LawGas boilers for heating or hot water get an efficiency check every 4 years (10–100 kW) or every 2 years (100 kW or more) (DPR 74/2013). No national law sets an interval for gas cooking appliances; a qualified installer fits them and maintenance follows the maker’s instructions.
  • LawBars and restaurants do not need a fire prevention certificate. Attached activities do, for example a heat plant over 116 kW (DPR 151/2011).
  • LawEvery employer does a fire risk assessment. An emergency plan is needed with 10 or more workers, or with more than 50 people present at once.