Luksemburg: požarna varnost
Preverjanja požarne varnosti vaše kuhinje in kako pogosto jih je treba izvesti.
Checked
Pravila na tej strani so zaenkrat v angleščini. Prevedena bodo v vaš jezik.
»Zakon« je zavezujoče pravilo. »Uradne smernice« niso zakon, vendar jih inšpektorji pričakujejo. »Chef Hygiene privzeto« je vrednost, s katero aplikacija preveri, kadar nobeno pravilo ne določa številke.
- PravoRestaurants for more than 50 people are class 2 classified establishments. The commune gives the permit and sets its own conditions. Where the permit imposes ITM-SST rules 1501.6 or 1502.5, extinguishers must be checked at least every 24 months.
- PravoUnder the same ITM-SST rules, safety installations (fire equipment, hood extinguishing, gas detectors, alarm, emergency lights) are checked every year, and electrical installations every 5 years. Hold an evacuation drill every year.
- PravoKitchen hoods need automatic extinguishing if the oil reserve is over 100 litres. With 50 to 100 litres, use two 6-litre class F extinguishers or an automatic system. Kitchens also need extinguishers and a fire blanket (ITM-SST 1505.3). No hood cleaning interval was found.
- PravoGas boilers, water heaters and stoves over 4 kW need a review every 4 years by an authorised firm (RGD of 27 February 2010). The fire service (CGDIS) advises servicing gas heaters before each winter.
Uradni viri
- ALVA, food safety in Luxembourg
- Law of 2 April 2026 on food control, Legilux
- HORESCA hygiene guide 2022, ALVA
- Guichet.lu, food safety for businesses
- ITM, fire prevention conditions
Ta stran je splošna informacija in ne pravni nasvet. Za več informacij se obrnite na lokalne oblasti.